Access and Scheduling:
- Hours of Facility Operation:
- Daytime = 8:30 - 17:30 hr
- Evening = 17:30 - 23:00 hr
- Access Limits to LSR II, and FACScanto
by Trained Personnel from User Laboratories
- Access to the booking times depends
on whether or not your laboratory has defined itself as a frequent
user, and has paid the frequent user access fee. (See Classification
of Research Users.) The following rules apply.
- Research User Labs
- may book in advance, for any available day or
evening times
- Limits are:
- no limit on the evening schedule
- There is a limit
of 5 experiments, or 10 hours of use per week total time
during the daytime schedule for each user from a given
lab. For
each
lab,
there's a
limit of 6 hrs. during the daytime schedule, with two
or more users from one research lab.
- a total of no more than 8 experiments in
advance, on the daytime schedule
- no experiments will be scheduled more than
4 weeks in advance on the day schedule
- Access and Scheduling for LSR II
or FACScanto with Assistance of the Facility Operator
- To book and access for samples to be
run by the Operator, you must first contact the Operator.
You must describe the kind of experiment, cell type, fluorochromes,
etc. The Operator must be given your name and phone number, as well
as, a research billing account number and department of affiliation.
- If you have never used the LSRII or FACScanto
before, and are unsure about the experimental design for use
of these instruments,
contact the Facility Director.
- The Facility Operator is only available to run
samples during the daytime hours.
- (8:00-17:00 hrs).
- Access and Scheduling of VantageSE Instrument
- The Vantage instrument can only be operated
by a designated facility operator.
- To sign up, you must first contact the Operator
and discuss with her the kind of experiment, cell type, flourescent,
etc. Only after it is clear what is required will a scheduled time
by assigned. The Vantage Operator will enter your name and phone
number in the schedule for the agreed upon day and time. You must
give a billing account number to the Operator prior to the day you
use the Vantage.
- If you are uncertain if the Vantage instrument
is suitable for your experiments, then
first contact the Facility
Director.
- The Vantage instrument is available only
in daytime hours (8:00 - 17:00 hrs.)
Top of Document /
Main Page
General User And Sign Up Rules:
- Users must wear a lab coat with a security badge
at all times. Entry after 1700 hours may not be allowed otherwise.
All evening users from any laboratory must inform the Operator of
their name and security badge #, prior to the day they will use the
Facility.
- Any cancellation for use of any instrument
must be made at least 3 hours prior to the scheduled time. If you
must cancel a LSR II or FACScanto experiment, contact
the booking administrator(M-F) at
or
phone (x22970), and tell the Facility operator. Should this happen on a week-end call x21589 & notify person(email) booked before of after you. If cancelling
a Vantage appointment,
contact the Operator. This allows
others to make use of the time. Failure to make a proper cancellation
could
result in a 1 hour penalty charge.
Top of Document / Main
Page
LSRII, and FACScanto Booking Online and Log of User Hours:
Top of Document / Main
Page
Sample Preparation: (For All Instruments)
- ALL samples MUST be in one of two standard running
buffers:
- Buffer for Viable Cell Preparations
- PBS pH 7.0-7.5 - plus 1-10 mg/ml BSA (optional),
plus azide (optional)
- no pH color indicator dye should be present
- exceptions MUST be discussed with the Operator
or Facility Director in advance
- Fixed Cell Buffer
- Samples may be run with fixative, but this must
be low concentration (<1% paraformaldehyde) - No
Gluteraldehyde
- All samples should be washed free of unbound fluorescent
labels. If the experiment requires free label, preliminary work
must be done to ensure that the label will not "contaminate" the
instrument (check with Facility Operator or Director)
- Samples with large visible aggregates or suspended
particles MUST be filtered through nylon mesh (60 micron) prior
to run. Researchers should purchase their own nylon mesh in advance
and have available at the time of sample running.
- All samples MUST be in FALCON #2058 (12X75 mm)
tubes, (suggested retailer). NO SUBSTITUTES ACCEPTED. These fit
properly on both the FACScanto, LSRII and Vantage instruments.
- All samples brought to Facility by researchers
who are running their own samples must be capped
while in transport.
- All samples given to the Operator to run MUST be
capped
- All sample preparation (staining, washing, fixing)
must be completed before entering the Facility.
Top of Document / Main
Page
Data Handling:
- Each laboratory will have an assigned sub-directory
on each instrument computer. This is for
compiling data from the current
experiment. DO NOT leave data on the computer for long periods
of time. Occasional "purging" of the computer hard-drive is
done, with no view to saving your data. GET THE DATA OFF QUICK
OR LOSE IT!
- Data can be copied to floppy diskettes or to removable
ZIP disks, or writable CD. Each laboratory will have to purchase
their own diskettes, ZIP or CDs for storage.
- Diskettes, ZIP or CDs must be provided by
the researcher for the Facility Operator to use if data storage
is requested,
when the Operator runs the samples.